Faffe, Debora S., Byrne, Rachel, Body, Richard, Castiñeiras, Terezinha Marta P., Castiñeiras, Anna P., Finch, Lorna, Kontogianni, Konstantina, Bengey, Daisy, Galliez, Rafael Mello, Ferreira, Orlando C., Mariani, Diana, da Silva, Bianca Ortiz, Ribeiro, Sabrina Santana, de Vos, Margaretha, Escadafal, Camille, Adams, Emily ORCID: https://orcid.org/0000-0002-0816-2835, Tanuri, Amilcar and CubasAtienzar, Ana (2022) 'Multicenter Diagnostic Evaluation of a Novel Coronavirus Antigen Lateral Flow Test among Symptomatic Individuals in Brazil and the United Kingdom'. Microbiology Spectrum, Vol 10, Issue 6, e02012-22.
|
Text
spectrum.02012-22.pdf - Published Version Available under License Creative Commons Attribution. Download (267kB) | Preview |
Abstract
The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods.
Item Type: | Article |
---|---|
Corporate Authors: | LSTM Diagnostics Group, CONDOR Steering Group |
Subjects: | QW Microbiology and Immunology > Antigens and Antibodies. Toxins and Antitoxins > QW 573 Antigens QY Clinical Pathology > QY 4 General works WC Communicable Diseases > Virus Diseases > Viral Respiratory Tract Infections. Respirovirus Infections > WC 506 COVID-19 |
Faculty: Department: | Biological Sciences > Department of Tropical Disease Biology |
Digital Object Identifer (DOI): | https://doi.org/10.1128/spectrum.02012-22 |
SWORD Depositor: | JISC Pubrouter |
Depositing User: | JISC Pubrouter |
Date Deposited: | 03 Jan 2023 10:55 |
Last Modified: | 30 Jun 2023 13:44 |
URI: | https://archive.lstmed.ac.uk/id/eprint/21608 |
Statistics
Actions (login required)
Edit Item |